Customization: | Available |
---|---|
After-sales Service: | Performance Warranty |
Warranty: | 5years |
Suppliers with verified business licenses
Basic information | |||
Voltage | 125-500V | Rated Power | 3.6KW-8KW |
Trade Mark | Deye | Transportation Package | Carton Box |
Production Capacity | 1000/pcs/Month | Origin | Shenzhen |
Model | SUN-3.6K SG05LP1-EU |
SUN-5K SG05LP1-EU |
SUN-6K -SG05LP1-EL |
SUN-7.6K 5G05LP1-EU |
sSUN-8K SG05LP1-EU |
||
Battery Input Data | |||||||
Battery Type Lead-acid or Li-lon | |||||||
Battery Voltage Range (V) 40~60 | |||||||
Max.Charging Current (A) 90 | 120 | 135 | 190 | 190 | |||
Max.Discharging Current (A) 90 | 120 | 135 | 190 | 190 | |||
External Temperature Sensor Yes | |||||||
Charging Curve 3 Stages /Equalization | |||||||
Charging Strategy for Li-lon Battery | Self-adaption to BMS | ||||||
PV String Input Data | |||||||
Max.DC Input Power (W) 4680 | 6500 | 7800 | 9880 | 1040C | |||
Rated PV Input Voltage (V) | 370(125~500) | ||||||
Start-up Voltage (V) 125 | |||||||
MPPTVoltage Range (V) 150-425 | |||||||
ull Load DC Volt ge Range (V 300-425 | 200-425 | ||||||
PVInput Current(A) 13+13 | 26+26 | ||||||
Max.PVISC(A) 17+17 | 34+34 | ||||||
Number of MPPT/Strings per MPPT 2/1+1 | 2/2+2 | ||||||
AC Output Data | |||||||
Rated AC Output and UPS Power (W) | 3600 | 5000 | 6000 | 7600 | 8000 | ||
Max.AC Output Power (W) 3690 | 5500 | 6600 | 8360 | 8800 | |||
ACOutput Rated Current(A) | 16.4 | 22.7 | 27.3 | 34.5 | 36.4 | ||
Max.AC Current(A) 18 | 25 | 30 | 38 | 40 | |||
Max.Continuous ACPassthrough(A) | 35 | 40 | 50 | ||||
Peak Power(off grid) 2 time of rated power,10 S | |||||||
Power Factor 0.8 leading to 0.8 lagging | |||||||
Output Frequency and Voltage 50/60Hz;L/N/PE 220/230Vac (single phase) | |||||||
Grid Type Single Phase | |||||||
DC injection current (mA) | THD<3%(Linear load<1.5%) | ||||||
Efficiency | |||||||
97.60% | |||||||
Furo Efficiengy | 96.50% | ||||||
99.90% | |||||||
Protection | |||||||
PV Input Lightning Protection,Anti-islanding Protection,PV String Input Reverse Polarity Protection, Integrated Insulation Resistor Detection,Residual Current Monitoring Unit,Output Over Current Protection, Output Shorted Protection,Surge protection |
|||||||
Output Over Voltage Protection DC Type ll/AC Type I | |||||||
Certifications and Standards | |||||||
Grid Regulation | CEI0-21,VDE-AR-N 4105,NRS 097,IEC 62116,IEC 61727,G99,G98, | ||||||
VDE0126-1-1,RD 1699,C10-11 | |||||||
Safety EMC /Standard | IEC/EN 61000-6-1/2/3/4,IEC/EN 62109-1,IEC/EN 62109-2 | ||||||
General Data | |||||||
Operating Temperature Range (C) | -45~60ºC,>45ºC derating | ||||||
operation;Support multiple batteries paralle | Natural cooling | ||||||
<30 dB | |||||||
RS485;CAN | |||||||
24 | |||||||
330Wx580Hx232D | |||||||
IP65 | |||||||
Wall-mounted | |||||||
5 years |